Free shipping on order above PKR 30,000/-
Search
Close this search box.

Patient Monitor Vital Sign – ACCUIT Sign 5

Original price was: ₨ 48,000.Current price is: ₨ 45,000.

Star Seller. This seller consistently earned 5-star reviews, dispatched on time, and replied quickly to any messages they received.

– Ship Everywhere in Pakistan

Surgicals.pk Purchase Protection: We want you to love our products. If you are not completely satisfied with your purchase you can return it free within 7 days, no questions asked. Learn more

Description

FEATURES:

  • Is applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
  • Is applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
  • Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
  • Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
  • With user-friendly interface.
  • Display with 2.8” (320×240) color TFT LCD and red and yellow highlight LED.
  • Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
  • Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.
  • Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.

 

PERFORMANCE:

  • 1. NIBP monitoring
  • Measurement method: Oscillometry
  • Measurement mode: manual/auto/continuous.
  • Auto measurement interval: adjustable from 1 to 90 minutes.
  • Resolution: 1mmHg.
  • Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
  • Self-check function.
  • Overpressure protection: double protection for software and hardware.

1) Range:

  • A. Adult:
  • Systolic pressure: 40mmHg~270mmHg
  • Mean pressure: 20mmHg~235mmHg
  • Diastolic Pressure: 10mmHg~215mmHg
  • B. Pediatric:
  • Systolic pressure: 40mmHg~200mmHg
  • Mean pressure: 20mmHg~165mmHg
  • Diastolic Pressure: 10mmHg~150mmHg
  • C. Neonatal:
  • Systolic pressure: 40mmHg~135mmHg
  • Mean pressure: 20mmHg~110mmHg
  • Diastolic Pressure: 10mmHg~100mmHg

2) Upper and lower limit of alarm:

  • A. Adult:
  • Systolic pressure: 40mmHg~270mmHg
  • Mean pressure: 20mmHg~235mmHg
  • Diastolic Pressure: 10mmHg~215mmHg
  • B. Pediatric:
  • Systolic pressure: 40mmHg~200mmHg
  • Mean pressure: 20mmHg~165mmHg
  • Diastolic Pressure: 10mmHg~150mmHg
  • C. Neonatal:
  • Systolic pressure: 40mmHg~135mmHg
  • Mean pressure: 20mmHg~110mmHg
  • Diastolic Pressure: 10mmHg~100mmHg
  • 2. SpO2 monitoring
  • Continuous real-time measuring.
  • Adopt digital SpO2 technology, which has strong anti-interference capability.
  • Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
  • Standard finger-clip probe for adult , binding probe for neonatal is optional.
    • 1) SpO2 Measuring
    • Range: 35%~100% (Resolution: 1%)
    • Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
    • 2) Pulse Rate Measuring
    • Range: 30bpm~250bpm(Resolution: 1bpm)
    • Accuracy: ±2bpm or ±2%, whichever is greater.
    • 3) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
    • 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

 

ACCESSORIES:

  • A power cord
  • A power adapter
  • A SpO2 probe
  • An adult NIBP cuff
  • An extending tube for blood pressure

 

PHYSICAL CHARACTERISTICS:

  • Dimension for prodult: 190(L)×162(W)×240(H)mm
  • Weight: 1.6kg
  • Dimension for packaging: 402(L)×228(W)×320(H)mm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

×